General Safety Instructions for 230V Machines
8
If the particle fi lter starts to clog, this reduces the air
fl ow and hence the machine becomes less effi cient.
The particle fi lter can be cleaned, by using an ‘M’ class
vacuum cleaner, clean the inside of the fi lter.
Be aware that in dry air periods or areas, the movement
of the air through the machine can generate static
electric fi elds. This is not normally a problem as the
machine is bonded together via its construction and
the whole is earthed back through the electrical supply.
Problems can occur with isolated items, such as stands or
hosing that
are insulated from the ground (standing on
rubber feet), suspended in the air etc.
If possible, try to connect everything together electrically,
to eliminate static shocks.
(Use the integral metal coil in fl exible plastic hosing to
connect units together).
Try to route the power cable and the hosing away from
busy walkways.
Do not allow the inlet to become ‘dead ended’, or block
or restrict the outlet, this puts undue strain on the motor
and can lead to overheating.
NOTE: DO NOT FIT PLASTIC WASTE BAGS TO THIS MACHINE!
Please read through the section entitled Parts Identifi cation and Description, this will enable you to more readily
identify those parts of the cyclone extractor.
Please note: some of this assembly procedure is best accomplished by two persons. Although
the tasks are not impossible, some of the items are heavy and awkward, and a mishandling
error could cause injury. Please think about what you are doing, your capabilities and your
personal safety. We have added the ‘two person symbol’ to any operation that we recommend
should be a two person task.
Unpack all the boxes and check all the components listed in the “What’s Included” section. If any parts or
components are missing, please contact our Customer Services Department using the procedures and telephone
numbers listed in our catalogue.
Please note: on occasions the packing list is not strictly adhered to. Please check all the boxes, packets
etc. to make sure that all the parts have been accounted for.
PLEASE RECYCLE ANY UNWANTED PACKAGING RESPONSIBLY!
Model T-2000CK-200H
Code 508338
Rating Trade
Power 1.5kW (230V, 1ph)
Air Flow 2,300m³/hr
Noise Level 84dB @ 3m
Filter Area 7.4m²
Filtration 1 micron
Particle Size 1 micron
Hose Diameter 180mm x 1, 100mm x 2
Overall L x W x H 1,250 x 1,000 x 1,800mm
Weight 83kg